Sign In | Join Free | My uabig.com
China Surplus Industrial Technology Limited logo
Surplus Industrial Technology Limited
Surplus Industrial Technology Limited We offer a variety of equipment for heating high-purity fluids and gases, including chemical PFA/PTFE Inline heaters, deionized water heater, PTFE heat exchanger
Verified Supplier

1 Years

Home > PTFE Heat Exchanger >

Hot Sulfuric Acid Heat Exchanger , Teflon Immersion Heat Exchanger Rugged Design

Surplus Industrial Technology Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Hot Sulfuric Acid Heat Exchanger , Teflon Immersion Heat Exchanger Rugged Design

  • 1
  • 2

Brand Name : Surplus

Model Number : PTFE Heat Exchanger 07

Certification : ISO9001,CE

Place of Origin : China

MOQ : 1 PCS

Price : Negotiable

Payment Terms : T/T,

Supply Ability : 50 PC/Month

Delivery Time : 10-15 working days

Packaging Details : Wooden Case or Carton Box

Name : Hot Sulfuric Acid (150 °C) Disposal Coller Immersion PTFE Heat Exchanger

Frame Material : PTFE,PP,PVC,PVDF

Tube Material : PFA,PTFE,FEP

Connections : 1/2" FNPT or others

Pressure : 30 PSI

Size : can designed as requirements

Contact Now

Hot Sulfuric Acid (150 °C) Disposal Coller Immersion PTFE Heat Exchanger

Excellent chemical compatibility and rugged design for your heating or cooling application.
All wetted parts of fluoropolymer (FEP, PFA or PTFE) construction.
Eliminates stray currents.
PFA coils are available for steam service up to 60 PSI.
10 PSI minimum steam pressure required for operation.

Robust Design


The Coil is designed to eliminate stray currents in tanks and offers excellent chemical compatibility with a rugged design ideal for heating or cooling applications.

All wetted parts are constructed from durable fluoropolymer materials (FEP, PFA, or PTFE), ensuring superior performance and longevity.

The heavy-duty CPVC mounting bracket provides robust support, while standard FEP coils are rated for up to 30 PSI steam service, and PFA coils can handle up to 60 PSI steam pressure.

The coil’s heavy wall tubing improves circulation, reduces pressure drop, and a 1/8-inch perforated guard offers protection from damage.

Integral inlet/outlet connections reduce potential leaks, ensuring reliable operation.

Vacuum breakers are recommended for fluoropolymer heat coil steam heating installations.

Features & Values

All wetted parts of fluoropolymer(FEP,PFA or PTFE) construction with a heavy duty CPVC mounting bracket.

Heavy wall tubing improves circulation and minimizes pressure drop. Larger coils constructed of 1/2 inch(13mm) tubing, smaller coils have 1/4 inch(7mm) tubing.

Integral inlet and outlet manifolds for single point connections greatly reduce the potential for leaks and simplify installation.

Eliminates stray currents in the tank.

Industries

  • Semiconductor Fabrication
  • Solar Cell Manufacturing
  • Flat-Panel Display, LEDs & Electronics
  • Chemicals Manufacturing
  • Industrial Manufacturing

Others Applications

Acid Heating And Corrosive Chemical Heating

Built to withstand the stress of acids or other corrosive chemicals while maintaining the highest quality and safety standards, Process Technology fluoropolymer (PTFE) heaters and exchangers are engineered to perform.

Acid Heating And Corrosive Chemical Heating(1)
3HX SeriesHot Sulfuric Acid Heat Exchanger , Teflon Immersion Heat Exchanger Rugged Design

HXT SERIES – SCREWPLUG

Hot Sulfuric Acid Heat Exchanger , Teflon Immersion Heat Exchanger Rugged Design

9HX SERIES

Hot Sulfuric Acid Heat Exchanger , Teflon Immersion Heat Exchanger Rugged Design

6HX SERIES

Hot Sulfuric Acid Heat Exchanger , Teflon Immersion Heat Exchanger Rugged Design

3HXOL SERIES Hot Sulfuric Acid Heat Exchanger , Teflon Immersion Heat Exchanger Rugged Design

HXSL SERIES

Hot Sulfuric Acid Heat Exchanger , Teflon Immersion Heat Exchanger Rugged Design

Chemical Heating

Fluoropolymer (PTFE) heater and heating components are engineered with protection from corrosive chemicals while maintaining the highest quality and safety standards.

Chemical Heating(2)

HXT SERIES – SCREWPLUG
Low watt density, spiral screwplug heater. Fluoropolymer (PTFE) sleeved 304 stainless elements inert to most solutions. 1000-6000 watts, 120-600 volts.

Hot Sulfuric Acid Heat Exchanger , Teflon Immersion Heat Exchanger Rugged Design

HXOL SERIES
Low watt density, flexible riser, bottom heater. Fluoropolymer (PTFE) sleeved 304 stainless elements inert to most solutions. 1000-6000 watts, 120-600 volts.

Hot Sulfuric Acid Heat Exchanger , Teflon Immersion Heat Exchanger Rugged Design


Product Tags:

Rugged Design Immersion Heat Exchanger

      

Teflon Sulfuric Acid Heat Exchanger

      

Teflon Immersion Acid Heat Exchanger

      
Wholesale Hot Sulfuric Acid Heat Exchanger , Teflon Immersion Heat Exchanger Rugged Design from china suppliers

Hot Sulfuric Acid Heat Exchanger , Teflon Immersion Heat Exchanger Rugged Design Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Surplus Industrial Technology Limited
*Subject:
*Message:
Characters Remaining: (0/3000)